top of page

GEN 1 Domestic Carbon Monoxide Sensor

Physical

Weight

Housing Material

8 grams

ABS

Product Image

Environmental

Temperature Range

Pressure Range

Humidity Range

Operational Life

Recommended 

Storage Conditions

-20°c to +52°c

1 Atmosphere -20% to +10%

Continuous: 15% to 90% 

Intermittent: 0% to 99%

Greater than 10 years

+10°c to +30°c (shorted)

Electrical

Bias Voltage

Offset Voltage

Recommended

Storage Conditions

Not required

<10mV (Absolute Maximum)

<1mV (Recommended)

820R (Absolute Maximum)

Output Parameters

Output Signal

Measurement Range

Maximum Overload

Response Time

(T90)

Baseline Offset

(clean air)

Zero Shift

(-20°c to +52°c)

Linearity

Repeatability

Long Term

Output Drift

Orientation

11±4 nA/ppm

0-500 ppm

5000ppm

<50 seconds

-2ppm to +2ppm

<+5ppm

Typically ±5% or better

<±10%

<10% pa

Any

Gen 1 Carbon Monoxide Sensor
Gen 1 dimensions

Dimensions (mm)

Gas

Carbon Monoxide

Ethanol

Ethanol

HMDS

Nitric Oxide

Hydrogen

Carbon Dioxide

Sulphur Dioxide

Concentration

/ppm

100

2000

200

10

50

100

5000

50

Exposure Time

/mins

5

20

120

40

5

10

5

5

Equivalent Reading

/ppm

100

0

0

0

0

<30

0

0

Cross Sensitivity Information

Cross sensitivity data is generated from a limited number of cells and the data above represents expected values for all cells. However a degree of variation may exist for specific sensors. All measurements taken at 25°C at a humidity of between 30% and 50%RH and at atmospheric pressure unless otherwise stated. All measurements made on cells less than 6 months after manufacture.

Signal Conditioning

          The 'Gen1' is a 2-terminal amperometric electrochemical sensor, delivering a current that is proportional

to CO concentration. The bias voltage across its terminals should be kept as low as possible to maintain optimum stability and accuracy.

          A transimpedance amplifier is an effective means of monitoring this current while maintaining a very low bias across the sensor. The op-amp should have low input bias currents (<5nA) and a low input offset (±1mV

maximum recommended).

Signal Conditioning
bottom of page